Skip to content

Draft — not approved. A working draft by UASK. It may change without notice.

Architecture description

Used in the playbook Project foundation.

The source, as in the repository: architecture-description.md Download

How to use

The template's own instructions:

UASK Engineering Hub template · architecture-description 0.1.0 · item arch.architecture-description · playbook mgmt.project-foundation standards: ISO/IEC/IEEE 42010:2022, arc42 template (twelve sections, as shown on docs.arc42.org, accessed 2026-11-22; the site names no edition) Use it when a system or a subsystem needs an architecture description of its own and the Blueprint (templates/blueprint.md) is not the right place: a large system described in parts, an existing system recorded for an architecture review (as-is), or a client who asks for the description in the arc42 order. The section order follows arc42 by reference; the text of every section below is the Hub's own and arc42's text is not copied (arch.architecture-description R13). For a normal new product use the Blueprint, which has the same twelve sections and the tiers, and do not keep both for one system. Save as project/architecture/<slug>.md. Diagrams as code (C4, item arch.c4-model) stay in this file. Mark every significant or hard-to-reverse choice with **[ADR-NNNN]** linking to its record. Delete these comments in the copy.

Fields

Front-matter fields and sections of the document the template creates. A section marked Optional in the template may be deleted from a copy; every other field and section stays (tools/check_artifacts.py checks this for the kinds it knows).

Field or sectionWhereRequired
templatefront matterrequired
titlefront matterrequired
statusfront matterrequired
versionfront matterrequired
datefront matterrequired
ownerfront matterrequired
tierfront matterrequired
Introduction and goalssectionrequired
Constraintssectionrequired
Context and scopesectionrequired
Solution strategysectionrequired
Building block viewsectionrequired
Runtime viewsectionrequired
Deployment viewsectionrequired
Cross-cutting conceptssectionrequired
Architecture decisionssectionrequired
Quality requirementssectionrequired
Risks and technical debtsectionrequired
Glossarysectionrequired
Sourcessectionrequired

Example

A filled-in copy for an invented product, templates/examples/architecture-description.md, in the Hub repository.It shows the level of detail to aim for, not text to reuse.

example-architecture-description.md
---
template: architecture-description/1
title: Architecture description
status: draft
version: 0.1.0
date: 2026-03-04
owner: Product Owner
tier: standard
---
# Architecture description — Fieldnotes storage and sync
## Introduction and goals
Fieldnotes keeps notes as plain files on the device and syncs them through Git. This description covers storage and sync, the part that
holds the user's data. Goals: no note is ever lost (NFR-1), it works fully offline, and the files can be read without the app.
Stakeholders: the user, who cares about not losing notes; Sam Roe, who maintains it and cares about a small codebase.
## Constraints
| Constraint | Source |
|---|---|
| Runs on phones from Android 10 | PRD, constraints |
| No server of our own to run or pay for | owner, 2026-03-01 |
## Context and scope
```mermaid
flowchart LR
user["User<br/>[Person]"] -->|writes notes| app["Fieldnotes<br/>[Software system]"]
app -->|push and pull| git["Git host<br/>[Software system]"]
```
| Interface | Direction | Contract or owner |
|---|---|---|
| Git host over HTTPS | both | the user's host; the Git protocol |
## Solution strategy
| Concern | Choice | Decision |
|---|---|---|
| Storage | Markdown files in Git | [ADR-0002](decisions/0002-notes-as-files.md) |
## Building block view
Two containers inside the app. The **note store** reads and writes the files and owns the save order (write a temporary file, then rename).
The **sync** block calls the Git library to push and pull and depends on the note store only.
## Runtime view
Save: the editor hands the text to the note store, which writes `<id>.md.tmp`, flushes it and renames it. If the app is killed in the middle,
the next start deletes the temporary file and opens the last complete note.
## Deployment view
The app is built in CI and published as a signed package. Notes live in the app's private folder; backup is the user's Git remote.
Rollback of a release is the previous package; the files do not change between versions.
## Cross-cutting concepts
Errors in storage are shown to the user and never swallowed. There is no logging of note text. Configuration is a single settings file.
## Architecture decisions
- [ADR-0002](decisions/0002-notes-as-files.md) — Store notes as plain files in Git.
## Quality requirements
| Scenario | Measure |
|---|---|
| The app is killed during a save of a 1 MB note | the previous version opens; 0 of 100 kills lose a note |
| A note of 10 000 characters is opened | under 300 ms on the reference phone |
## Risks and technical debt
| Risk | Likelihood | Response | Owner |
|---|---|---|---|
| Two devices edit one note offline | medium | the later change wins and the earlier is kept as a copy | Sam Roe |
## Glossary
- **Note store** — the block that writes and reads note files.
## Sources
- [arc42 template](https://docs.arc42.org/home/), as shown on docs.arc42.org, accessed 2026-11-22; the site names no edition. CC BY-SA 4.0;
referenced for the order of the twelve sections only, not copied.
- ISO/IEC/IEEE 42010:2022, Software, systems and enterprise — Architecture description — terms and concerns, not the wording.

Completion checks

A copy is complete when:

  • every required field and section above is present, in the same order, and no bracketed placeholder is left;
  • the template's comments are deleted from the copy;
  • the exit criteria of its stage of the playbook Project foundation are met;
  • the owner has approved it, where the playbook asks for approval. Only the owner sets approved.

Source

templates/architecture-description.md, as in the repository. Placeholders are in square brackets; comments carry the instructions.

architecture-description.md
---
template: architecture-description/1
title: Architecture description
status: draft # draft | review | approved — only the owner sets approved
version: 0.1.0
date: YYYY-MM-DD
owner: Product Owner
tier: standard # lightweight | standard | high-assurance — the owner decides (mgmt.governance-tiers)
---
# Architecture description — System or subsystem name
<!--
UASK Engineering Hub template · architecture-description 0.1.0 · item arch.architecture-description · playbook mgmt.project-foundation
standards: ISO/IEC/IEEE 42010:2022, arc42 template (twelve sections, as shown on docs.arc42.org, accessed 2026-11-22; the site names no edition)
Use it when a system or a subsystem needs an architecture description of its own and the Blueprint (templates/blueprint.md) is
not the right place: a large system described in parts, an existing system recorded for an architecture review (as-is), or a
client who asks for the description in the arc42 order. The section order follows arc42 by reference; the text of every
section below is the Hub's own and arc42's text is not copied (arch.architecture-description R13). For a normal new
product use the Blueprint, which has the same twelve sections and the tiers, and do not keep both for one system.
Save as project/architecture/<slug>.md. Diagrams as code (C4, item arch.c4-model) stay in this file. Mark every significant
or hard-to-reverse choice with **[ADR-NNNN]** linking to its record. Delete these comments in the copy.
-->
## Introduction and goals
<!-- What the system is for, the three to five quality goals that matter most and the stakeholders with their concerns. -->
## Constraints
<!-- Technical, organisational, legal and platform givens, each with its source. -->
## Context and scope
<!-- C4 level 1: people, this system, external systems; then the inventory of interfaces, each with a contract or an owner
(item arch.context-and-interfaces). -->
```mermaid
flowchart LR
user["User<br/>[Person]"] -->|uses| sys["System name<br/>[Software system]"]
```
## Solution strategy
<!-- The key choices, each linked to its ADR, and how responsibilities are separated. -->
| Concern | Choice | Decision |
|---|---|---|
| … | … | [ADR-NNNN](decisions/NNNN-….md) |
## Building block view
<!-- C4 levels 2 and 3: containers and components, each with its responsibility and what it depends on. -->
## Runtime view
<!-- The few flows that show how the blocks work together, as sequence diagrams or numbered steps; include one
failure flow. -->
## Deployment view
<!-- Where the blocks run, how they are built, released and rolled back, and how the data is backed up and restored. -->
## Cross-cutting concepts
<!-- Rules that cut across blocks: security, error handling, logging, configuration, data model, tests. -->
## Architecture decisions
<!-- The list of ADRs that shape the system, with one line each; the records live in project/decisions/. -->
## Quality requirements
<!-- The quality goals as scenarios that can be tested (source, stimulus, response, measure); item arch.quality-attributes. -->
## Risks and technical debt
<!-- Known risks and debts, each with an owner, a likelihood and a planned response. -->
## Glossary
<!-- Terms the readers need, one line each; a term from the Hub's glossary is linked, not redefined. -->
## Sources
<!-- Keep this section in the copy. -->
- [arc42 template](https://docs.arc42.org/home/), as shown on docs.arc42.org, accessed 2026-11-22; the site names no edition. CC BY-SA 4.0;
referenced for the order of the twelve sections only, not copied.
- ISO/IEC/IEEE 42010:2022, Software, systems and enterprise — Architecture description — terms and concerns, not the wording.